LP Turbine Bypass pressure reduction valve Pos. 9

LP Turbine Bypass
pressure reduction valve Pos. 9

Fluid: Steam
Pressure: 5 bar
Temperature: 250°C
Typical dimmensions: DN400-500
Pressure rating: PN25
Valve type: Butterfly, wafer type VSS
Actuator type: Pneumatic
Material valve body: EN 1.4408, EN 1.4552
Seat/lining: EN 1.4835
Operation: Control with separate quick close function.
Datasheet: Si-209
Comment: LP Turbine Bypass pressure reduction valve.

System info
LP Turbine Bypass valve is used during Start-up, at turbine-trip and at house load operation.

 