Continuous Digester HIC-027 CONTINUOUS DIGESTER HIC-027 Process dataFluid: Filtrate (from digester booster pump)Pressure: 7-13 bar (e) (normal ~10 bar)Temperature: About 85-110 °CTypical dimensions: 100-150, 1000-2000 ADt/dPressure rating: PN 25Valve descriptionDN 100Ball segment valve type KVTW.Seat in PTFE.Double acting type actuator.For more information see data sheets Si-113 EN and Si-114 EN. DN 125-150Butterfly valve type MTV.Seat in SS 2377.Double acting type actuator.For more information see data sheet Si-205 EN. CommentsSee general recommendations.