continuous digester HIC-063

continuous digester HIC-063

Process data

Fluid: Pulp to blow tank or washer followed by blow tank
Pressure: 5-13 bar (e) (max 16 bar)
Temperature: 90-130 °C
Consistency: 10%
Typical dimensions150-300, 1000-2000 ADt/d 
Pressure ratingPN 25 

Valve description

Ball valve type SKV.
Seat in HiCo (High cobalt alloy) A HiCo-coated ball is
preferable in order to increase time of operation.
Double acting type actuator.
For more information see data sheet Si-706 EN.

 

Comments

Blow line flow control is one of the most difficult applications within the pulp- and paper industry.
Beside the pulp, there are different types of inpurities
in the fluid that create erosion.
High differential pressure also gives a contribution to
increased erosion as well as vibrations.
 
See general recommendations.