continous digester HS-053

Continuous digester hs-053

Process data

Fluid: Digester vent gas (and accidently mill air)
Pressure: range 1-10 bar (e) (normal digester top pressure 4.5 bar)
Temperature: 10-170 °C (max 170 °C)
Typical dimensions: Valve A and B: 100-150, 1000-2000 ADt/d
Pressure ratingPN 25

Valve description

Butterfly valve type MTV.
Seat in SS 2377.
Double acting type actuator.
For more information see data sheet Si-205 EN.

 