Continuous digester PIC 041B

CONTINUOUS DIGESTER PIC 041B

Process data

Fluid: Digester vent gas (and accidently mill air)
Pressure: Range 1-10 bar (e) (normal digester top pressure 4.5 bar)
Temperature: 10-170 °C
Typical dimensions: 50-80, 1000-2000 ADt/d
Pressure ratingPN 25

Valve description

Ball segment valve type KVT/KVTW.
Seat in PTFE 53.
Double acting type actuator.
For more information see data sheets
Si-101 EN (DN 50-65) (KVT), Si-113 EN and Si-114 EN (DN 80) (KVTW)
 

Comments