Oxygen Delignification and Post Oxygen Washing FIC-504

Oxygen Delignification and Post Oxygen Washing FIC-504

PROCESS DATA

Fluid: Oxidised white liquor or NaOH
Pressure: 2-4 bar (e)
Temperature: 70-85 °C
Typical dimensions: DN 25-80, 1000-2000 ADt/d
Pressure ratingPN 10

VALVE DESCRIPTION

Ball segment valve type KVT/KVTW.
Seat in PTFE.
Double acting type actuator.
These valves should have Rulon® bearings.
Oxydized white liqour requires unchromed segments, NaOH does not.
 
For more information see data sheet
Si-101 EN (DN 25-65) (KVT), Si-113 EN and Si-114 EN (DN 80) (KVTW).

 