Oxygen Delignification and Post Oxygen Washing FIC-519

OXYGEN DELIGNIFICATION AND POST OXYGEN WASHING FIC-519

PROCESS DATA

Fluid: Oxygen (O2)
Pressure: 10-17 bar (e)
Temperature: 20-30 °C 
Typical dimensions: DN 25-40, 1000-2000 ADt/d
Pressure ratingPN 25

VALVE DESCRIPTION

Ball segment valve type KVT.
Seat in glass fibre re-inforced PTFE.
Double acting type actuator.
For more information see data sheet Si-101 EN.

 

COMMENTS

Degreased for oxygen service.