Pulp screening and washing HIC-311
PULP SCREENING AND WASHING HIC-311
Process data
Fluid: Pulp to diffuser or blow tank, two valves
Pressure: 4-11 bar (e) (max 15 bar)
Temperature: 80- < 100 °C
Consistency: 10%
Typical dimensions: Valve A and B:DN 300-500, 1000-2000 ADt/d
Pressure rating: PN 25
Valve description
Ball segment valve type KVMF (V-notch). Full Bore (B-body).
Seat in HiCo (high cobalt alloy).
Double acting type actuator.
For more information see data sheet Si-110 EN.
Alternative:
A flanged Ball valve type SKV.
Seat in HiCo (high cobalt alloy).
Double acting type actuator.
For more information see data sheet Si-706 EN.